Climate Setting Schedules

Climate Setting Schedules allow users to program customized temperature control schedules for their thermostat.

A climate setting schedule enables you to configure a thermostat HVAC mode setting (heat, cool, heat-cool/auto, or off) and desired temperature set points during a time frame.

For example, if you are a short-term-rental host who has a guest staying from Jan 1st - Jan 7th, you can create a climate setting schedule that sets the thermostat to a climate setting (for example, heat to 70° C) throughout the guest's stay.

When there are no active climate setting schedules, the thermostat falls back to the default climate setting. For example, if you are a short-term-rental host, you can configure a more energy-saving temperature setting as the default (for example, heat to 45° C).

climate_setting_schedule Properties

climate_setting_schedule_id

string

ID of the Climate Setting Schedule

device_id

string

ID of thermostat the Climate Setting Schedule is programmed on

name

string

Name of the Climate Setting Schedule

schedule_starts_at

ISO8601 date string

Date time when the Climate Setting Schedule will start

schedule_ends_at

ISO8601 date string

Date time when the Climate Setting Schedule will end

created_at

ISO8601 date string

Date time when the Climate Setting Schedule was created

is_set_on_device

boolean Readonly

If true, the climate setting schedule is currently active on the device.

automatic_heating_enabled

boolean Default: false

Whether the thermostat has heating turned on

automatic_cooling_enabled

boolean Default: false

Whether the thermostat has cooling turned on

hvac_mode_setting

heat_cool | heat | cool | off

The HVAC mode the thermostat is set to.

cooling_set_point_fahrenheit

number | null

When automatic_cooling_enabled is true, the thermostat will start cooling to maintain this temperature set point.

heating_set_point_fahrenheit

number | null

When automatic_heating_enabled is true, the thermostat will start heating to maintain this temperature set point.

manual_override_enabled

boolean Default: true

Whether another user can use the thermostat or API to override this climate setting

Last updated